Supply Disruption

A fuel becomes scarce or expensive, a plant goes offline, or the rains fail

A disruption such as a conflict that closes a major shipping route shows up in a power model in a few distinct ways. Each has a natural lever in a VerveStacks model.

What is in the model today

Disruption Lever already in the model
Fuel price shock (gas, oil, coal) Base-year low and high prices for each fuel by country, and AR6 price pathways to 2050, in the scenario files. See Fuel and Carbon Prices.
Loss of specific plants Large units are in the model one by one, by name, location and age, so a named plant can be taken out from a given year.
Drought Hydro availability options include a median year and dry (P10) and wet (P90) variants. See Hydro Availability Scenarios.
Loss of imports Cross-border trade is given at each border node in a country model, so it can be cut or reduced at the border where it happens.
Loss of a grid corridor Each corridor between nodes is its own process, with its own capacity.

What the user sets

  • The size and timing of the shock: a price multiplier for one fuel in a year or a run of years; a cap on how much of a fuel can be used (ACT_BND or a bound on the fuel commodity); the plants or corridors that go offline and when.
  • Whether the shock is expected. A shock written into a scenario from the start is one the model plans for. To see the cost of being surprised, fix the reference model's investments and re-run with the shock.

What it can show

  • Which plants and fuels take up the slack, and at which nodes.
  • The cost of the disruption, and how much of it a different mix (more storage, more interconnection, more renewables) would have avoided.
  • How a disruption interacts with a climate scenario: a gas shock under a C4 carbon price is a different event from the same shock under C1.

Not built yet

  • The reference model is a planning model over time slices. It shows how plans and costs change, not how the system behaves hour by hour in the first days of a crisis.
  • Fuel supply chains (LNG terminals, pipelines, refineries) are not represented in the power-sector models; a fuel shock enters as a price or a quantity at the power plant.